LB FEATURES
LBT - Bottom intake, top discharge
LBF - Front intake, top discharge
Two piece all aluminum, 12 gauge front and back.
- Extended backs and fronts available.
- 4" junction boxes at each end.
- 3/4" EMT raceway standard.
- 1/2" and 3/4" knockouts.
- Control packages available.
- In house engineering and design assistance.
- Custom selection of convector lengths from 2' to 12' length in
1/16" increments.
- Multiple heater sections on one common back.
- UL and CUL listed.
- Full length thermal limit switch.
- There are 5 anodized finishes available, six durable Decorator
painted finishes and grey prime.
- Custom finishes specified by the architect are available.
- Available with optional 2" pedestals and finished back.
- 1/4" pencil proof discharge grill.
- Accessories include: end caps, wall trims, splice plates, corners
and blank sections.
- Cabinet size is 5"W x 7"H.
- Available with built in thermostat or disconnect.
- Wattages from 100 to 500 watts per foot. (Except 120 volt*)
Control sections include 6" or 12" with:
disconnect, thermostat, pneumatic relay, transformer relay, relay, fused disconnect
or duplex receptacle Standard built-in controls shall include thermostats
(single and double pole) and disconnect switches.
LBT, LBF, LB-PD
Suggested Engineering Specifications:
Model LB Architectural Draft Barriers shall be 7" high and 5" wide.
The front cover shall be 12 gauge extruded aluminum construction
suitable for Architectural, Commercial and Industrial use with 1/4" pencil
proof intake and discharge grills. The one piece cover shall be extruded
for maximum strength and shall be available in lengths up to 12'.
The cover shall be linear mount to the 12 gauge heater back with no visible fasteners. The 12 gauge heater back shall be suitable for mullion to mullion mounting.
Standard painted finishes or optional anodizing (see color chart)
shall be provided as specified by the architect. Color matching to
architects specifications are available as optional finishes.
Heat sections from 2' to 10' are available. All heaters shall contain
3/4" EMT built in raceway with factory wiring to provide field wiring
from either end when optional controls are not included.
1/2" and 3/4" knockouts shall be provided in the side and rear of
the heater junction box to permit end to end wiring. All blank sections
shall be fully enclosed to allow branch circuit wiring. All heaters
shall contain a full length thermal overheat protector with automatic
reset. Wattages shall be available from 100 to 500 watts per foot.
Heating elements shall be tubular stainless steel or aluminum tubing
with aluminum fins mechanically bonded to ensure efficient heat transfer.
Element fin temperature shall not exceed 350 degrees Fahrenheit
to ensure long element life. Elements shall be center anchored and
free floating in nylon bushings at each end.
Control sections include 6" or 12" with: disconnect, thermostat,
pneumatic relay, transformer relay, relay, fused disconnect or duplex
receptacle. Standard built-in controls shall include thermostats
(single and double pole) and disconnect switches.
Built-in controls shall be tamper proof and shall be adjustable
with a blade screwdriver through the discharge louver.
All heaters are Underwriters Laboratories listed.
LB-PD
LB-PD series shall have 2" adjustable pedestals and the heater back
will be painted to match the front cover.
Standard Painted Finishes:
Black, Bronze, Grey, Tan, White, Prime Grey
Available Anodized Finishes:
204, 311, 312, 313 and 315.
NOTE: Specify LBT-PD or LBF-PD when ordering.
Furniture, Drapes & Carpeting
Proper operation of heater requires free circulation of room air
through the heating element. Keep electrical cords, drapes, rugs
and other furnishings away from the heater. Furniture should be placed
no closer than 4" from the heater.
Drapes should clear the top of the heater by at least 12". Or, if
you prefer floor length drapes, they should clear the floor by 3",
and the minimum clearance from the back fold to the front cover should
be at least 4".
For best results when carpeting is involved in the installation,
allow clearance for carpet to be installed under the heaters and
corners. Rugs can be placed up to the heater provided that they are
not of
a thickness that would block the air-intake at the bottom of the
heater.
Controls Built-In
LB-ITS (thermostat) Single pole rated 22 amps, 120 - 227 volt. Adjustable through discharge grill, mounted in right hand junction box.
LB-ITD
Same as Above (double pole.)
LB-IDS (disconnect)
Double pole, rated 20 amps, 120 - 277 volt. Adjustable through discharge
grill, mounted in left junction box.
Control Sections LB-CS
6" Control Section
6" long and can be added to total enclosure length. Contains 1 or
2 controls. Right or left hand mounting (right hand is standard).
12" Control Section
12" long and can be added to total enclosure length. Contains 1,
2 or 3controls. Right or left hand mounting (right hand is standard).
PR (power relay), PE (Pneumatic relay), MDR (mercury relay) Single or double pole (specify). Rated 25 amps, Low or line volt coils (specify).
TR (transformer relay) Single pole, rated 19 amps, 120 - 277 volt. Contacts rated up to 277 volt (specify). Coils are 24 or 120 volt (specify).
DR (duplex receptacle)
Mounted on front cover. Rated 15 amps, 120 volt. Snap in type control
section mounting.
FDS (fused disconnect)
Fuse block with fuse and 20 amp disconnect switch. Control section
mounting.
|